[1]皇甫琴,徐小平,张湘丁.含钛硝酸-氢氟酸混合液中钛的测定[J].电镀与精饰,2014,(4):35-37.
点击复制
含钛硝酸-氢氟酸混合液中钛的测定(
)
《电镀与精饰》[ISSN:1001-3849/CN:12-1096/TG]
- 卷:
-
- 期数:
-
2014年4
- 页码:
-
35-37
- 栏目:
-
- 出版日期:
-
2019-06-07
文章信息/Info
- Title:
-
Determination of Titanium Content in Nitric Acid-Hydrofluoric Acid mixed Solution
- 作者:
-
皇甫琴; 徐小平; 张湘丁
-
中航工业南方航空工业(集团)有限公司
- 分类号:
-
O645.1;O657.3
- 摘要:
-
建立了二安替比啉甲烷分光光度法测定硝酸-氢氟酸混合溶液中钛含量的分析方法,进行了精密度和加标回收率试验。试验证明,相对标准偏差均小于2.0%(n=5),加标回收率为98.33%102.14%。该方法具有较高的精密度与准确度。
- Abstract:
-
The titanium content in nitric acid-hydrofluoric acid mixed solution was determinated by diantipyrylmethane spectrophotometry. The experiments with precision and standard addition recoveries were carried out. The tests indicate that all the values of RSD’S( n = 5) are less than 2. 0% and values of standard addition recovery are in the range from 98. 33% to 102. 14%. This method has high precision and accuracy.