[1]路亚娟,沈 晓,李晓征,等.doi: 10.3969/j.issn.1001-3849.2025.05.017一例镀层附着力不良引起的高压开关产品放电问题分析[J].电镀与精饰,2025,(05):115-119.
 Wu Rumeng*,Du Shuwang.An example of a high voltage switch product caused by poor plating adhesion Lu Yajuan1,2,3, Shenxiao1,2,3, Li Xiaozheng1,2,3, Lou Jingang1,2,3,[J].Plating & Finishing,2025,(05):115-119.
点击复制

doi: 10.3969/j.issn.1001-3849.2025.05.017一例镀层附着力不良引起的高压开关产品放电问题分析()

《电镀与精饰》[ISSN:1001-3849/CN:12-1096/TG]

卷:
期数:
2025年05
页码:
115-119
栏目:
出版日期:
2025-05-31

文章信息/Info

Title:
An example of a high voltage switch product caused by poor plating adhesion Lu Yajuan1,2,3, Shenxiao1,2,3, Li Xiaozheng1,2,3, Lou Jingang1,2,3,
作者:
路亚娟123沈 晓123李晓征123娄金钢123吴茹梦123*杜书万1
(1. 河南平高电气股份有限公司,河南 平顶山467001;2. 平高集团 表面处理及金属防腐实验室,河南 平顶山 467001 ;3. 平高集团 路亚娟创新工作室,河南 平顶山 467001)
Author(s):
Wu Rumeng123* Du Shuwang1
(1. HenanPinggao Electric Co., Ltd.,Pingdingshan 467001, China; 2. Lab of Surface Treatment and Metal Anti-corrosion, Pinggao Group, Pingdingshan 467001, China; 3. Lu Yajuan Innovation Studio, Pinggao Group, Pingdingshan 467001, China)
关键词:
高压电气放电银层脱落
Keywords:
high voltage electrical discharge silver layer peeling off
分类号:
TG17
文献标志码:
A
摘要:
高压开关设备内核心零部件压气缸为6063铝合金材质,外表面进行电镀银层,内腔进行硬质阳极氧化处理。本文针对该零件电镀银层脱落造成放电的一起事故,通过对镀层脱落部位基体及脱落镀层底面进行成分分析,确定剥离部位为中间过渡铜层。通过对不合格零部件加工过程排查,确定此次放电的原因是压气缸工装挂具导电不良造成银镀层附着力不良,高压开关设备运行过程中,镀层经受外力反复摩擦脱落,引起产品放电。后期为规避此类问题,提出了该类核心零部件电镀银过程中,关键控制点及问题的规避方案,为电镀银表面处理产品工艺过程控制,提供参考依据。
Abstract:
The pressure cylinder of the core parts in the high voltage switchgear is made of 6063 aluminum alloy. It is plated with a silver layer on the outer surface and undergoes a hard anodized treatment on the inner cavity. This article discusses an incident caused by the silver peeled off. By analyzing the composition of the substrate and the bottom surface of the peeled coating, it was determined that the peeling occurred at the intermediate copper layer. It was identified that the cause of the discharge was poor conductivity of the fixtures, resulting in poor adhesion of the silver coating. During the operation of the high voltage switchgear, the coating experienced repeated friction and detachment due to external forces, leading to product discharge. To avoid such issues in the future, key control points and problem mitigation strategies were proposed for the silver plating process of these core parts. This provides a reference for process control in the silver plating surface treatment of products

参考文献/References:

[1].许振明, 徐孝勉. 铝和镁的表面处理[M]. 上海: 上海科学技术文献出版社, 2005:1-4.
[2].盛曦霆. 铝合金表面硬质阳极氧化制备工艺及性能研究[D]. 长春: 长春工业大学, 2022.
[3].郝留成, 廉继英, 周瑛, 等. 6063铝合金材料镀银层脱落原因及其解决途径[J]. 铸造技术, 2009, 30(10):1350-1352.
[4].王斌, 李晓征, 张颖杰, 等. 一例元素富集引起的6A02铝合金电镀银层起泡故障分析和解决[J]. 电镀与涂饰, 2020, 39(1):16-19.
[5].付国华, 张礼学. 铝合金微波腔体表面处理工艺[J]. 电镀与涂饰, 2022, 41(8):571-573.
[6].张策, 张德忠, 郭俊灏, 等. 铝合金阳极氧化膜低温无镍封孔工艺及其封孔性能[J]. 电镀与精饰, 2024, 46(1):20-27.
[7].王旗, 张尹航, 张晓云. 碱蚀对铝合金常温硬质阳极氧化膜性能的影响[J]. 材料保护, 2023, 56(10):161-165.
[8].赵旭辉, 左禹, 赵景茂. 几种封闭方法处理后铝阳极氧化膜的耐蚀性比较[J]. 腐蚀与防护, 2006, 27(8):400-403.
[9].韩克, 欧忠文, 蒲滕. 铝及铝合金硬质阳极氧化的研究进展[J]. 表面技术, 2011, 40(5):92-96.
[10].路亚娟, 李晓征, 马迎春, 等. 一例放电事故造成硬氧膜脱落的原因分析[J]. 电镀与精饰, 2023, 45(1):92-97.
[11].余爽, 赵科. 一起1100kV气体绝缘金属封闭开关设备母线放电故障分析[J]. 电气技术, 2021, 4(22):1-4.
[12].Liu Z H, Zheng X Y, Zhang H Wi, et al. Review on formation of biofouling in the marine environment and functionalization of new marine antifouling coatings[J]. Journal of Materias Science, 2022, 57(39):18221-18242.

相似文献/References:

[1]路亚娟 *,李晓征,马迎春,等.一例放电事故造成硬氧膜脱落的原因分析[J].电镀与精饰,2023,(1):92.[doi:10.3969/j.issn.1001-3849.2023.01.014]
 Lu Yajuan *,Li Xiaozheng,Ma Yingchun,et al.Reason analysis of hard anodic oxide film falling off caused by a discharge accident[J].Plating & Finishing,2023,(05):92.[doi:10.3969/j.issn.1001-3849.2023.01.014]